In เกจวัดความดันน้ำ from chemistry laboratories to industrial facilities, to be able to ensure the safety of life and property against a attainable hearth hazard, extinguishing methods are used in addition to detection and alarm systems. It can be extremely essential that the extinguishing techniques put in can be triggered by the hearth extinguishing control panel, to find a way to get rid of a potential hearth with early intervention.
In order to satisfy these needs, and with 35 years of sectoral information and experience, Mavili Elektronik presents:
Maxlogic Conventional Fire Extinguishing Control Panel operating based on the cross-zone detection principle;
Maxlogic Extinguishing Status Indicator Unit, which permits the distant efficiency of the indications and controls on the Control Panel;
Maxlogic Extinguishing Output Expansion Panel;
Maxlogic Extinguishant Manual Release Button, which allows the extinguishing course of to be started manually and remotely; and
to guarantee that the extinguishing process could be paused, Maxlogic has produced the Extinguishant Emergency Stop Button.
All these units are produced using surface-mount expertise and are aimed toward making the automation of the extinguishing system and fireplace and gas detection system excellent.
Image copyright: Mavili
Mavili Elektronik develops its merchandise by at all times contemplating the needs of the installation. In circumstances that require the combination of the extinguishing system with the clever addressable fire detection system, it supplies options by way of the monitoring modules that even have a ‘supervised’ choice.
Supervised monitoring modules play an important function in controlling the continuity of the cable connection between the loop and the extinguishing system. Failure to detect a possible open or brief circuit within the wiring between the contact monitoring modules and the peripheral techniques could cause disruption of the triggering, with potentially crucial penalties. For this cause, when choosing monitoring modules, it should be taken under consideration that they’ve supervised features.
Image copyright: Mavili
Since Maxlogic clever addressable fireplace detection and alarm management panels are continuously speaking with ‘supervise’ contact monitoring modules related to cable loops and compliant with EN 54-17 and EN 54-18 requirements, it makes it easier to watch conditions such as open circuits and short circuits which will occur in the system. Many duties could be performed within the hearth extinguishing installation, such as the management and monitoring of all valves that can interrupt the move of water, water circulate alarm switches, stress swap, and electrical or diesel fireplace pumps.
By including two contact monitoring modules to two separate relay outputs located above the Maxlogic Conventional Fire Extinguishing Control Panel, one of the modules can be utilized to control errors and the opposite to regulate the hearth situation, monitoring and management of the extinguishing system through an clever addressable hearth detection and alarm system may be carried out successfully.
For more info, go to www.mavili.com.tr/en